Goodman furnace codes
Got furnace problems?
Save Money Now! Call Today Next, make sure that there is power going to the furnace. This is how you can reset the breaker. Note: if the breaker is tripped that means there is a possibility of a short circuit in the furnace or electric wire, you then should call an HVAC contractor immediately. Remove the front cover of the furnace. You will see the top and bottom compartments of the furnace.
Goodman furnace codes
Refer to the furnace glossary if you need help identifying furnace parts or terms. All high-efficiency furnaces and most mid-efficiency furnaces show error codes on the control board, either as a flashing LED sequence or on a display. The furnace control board is almost always in the lower compartment. You can view the error code LED or display through a small, clear plastic inspection port in the centre of the lower furnace cover. Furnaces with upper and lower furnace covers — The inspection port is usually on the lower furnace cover and is accessible without removing the cover. Furnaces with a one-piece front cover — Remove the front cover first. The inspection port is usually on the secondary cover for the lower compartment. If the control board is in the upper compartment — You need to remove the upper furnace cover. If there are thumb screws, loosen them and pull the cover out from the screw location. If there are no screws, slide the cover straight up, then pull it out. Turning off the power clears the current error code. Observe the flashing LED sequence or display code, which may repeat in a loop. Watch it carefully, make note of the sequence or digits, and match it up with the corresponding code below:.
On this page:. Check for excessive wind, goodman furnace codes, proper vent sizing, defective inducer motor, low inducer voltage VACdefective pressure switch, inadequate combustion air supply, restricted vent, disconnected or obstructed pressure tubing. Pressure switch did not close or reopened.
FIX: You should check your thermostat for an improper setting or connection. FIX: After one hour of lockout, your furnace will automatically reset itself. FIX: You should either repair the short or replace the pressure switch. FIX: You should check the pressure switch hose for blocks or an improper connection. Otherwise, see if any loose wiring needs tightening.
If you own a Goodman furnace, you may encounter some error codes on the display panel that indicate a problem with your heating system. These codes are designed to help…. This post may contain affiliate links. Please read my disclosure policy. These codes are designed to help you identify the cause of the issue and take the appropriate steps to fix it. However, not all codes are easy to understand or resolve.
Goodman furnace codes
If you own a Goodman furnace, it is important to familiarize yourself with the various error codes that may appear on its display. These codes can help you identify and troubleshoot any issues that may arise with your furnace. In this comprehensive guide, we will discuss some of the most common Goodman furnace codes and their meanings. It may mean that the flame sensor is dirty or malfunctioning, or that there is an issue with the gas valve. In order to fix this issue, you may need to clean or replace the flame sensor, or have a professional technician inspect and repair the gas valve. If there is an issue with the pressure switch, it may mean that there is a blockage or restriction in the venting system, or that the switch itself is faulty. To resolve this issue, you may need to check for and clear any blockages in the venting system, or have a professional technician replace the pressure switch. It is important to note that these are just a few examples of the many error codes that may appear on your Goodman furnace. Each code has its own specific meaning and requires its own unique solution.
5 below
Meaning: Low flame error Potential Issue: Low gas pressure, faulty flame sensor, dirty flame sensor, etc. This will provide you with more detailed information about the problem and the steps you need to take to address it. How to access the inspection port Furnaces with upper and lower furnace covers — The inspection port is usually on the lower furnace cover and is accessible without removing the cover. Pressure switch error pressure switch closed with inducer off Issue with pressure switch, draft inducer not operating, debris in line, cracks in tubing, etc. Depending on the code, the steps to take may vary. These lights blink in specific patterns to represent specific issues. It can also cause a short circuit of the circuit board, blower motor, poor air quality, and rusting of the furnace. There are many different furnace brands, each with slightly different error codes. This is the result of a coated flame sensor or a lazy flame due to poor gas pressure. Here are the meanings of the other codes:. Schedule an Appointment.
Looking for how to identify Goodman Furnace error codes? Goodman furnaces have a display panel with a built-in trouble code that uses LED lights to show the homeowner that there is a malfunction of some sort.
In these cases, it is best to consult a professional. This will provide you with more detailed information about the problem and the steps you need to take to address it. Professional Diagnosis Required. Keeping the error codes in mind and following the tips mentioned in this guide can save you time, energy, and money in the long run. Meaning: Open pressure switch, induced draft blower on Potential Issue: Pressure switch hose cracked, blocked or improperly connected, faulty pressure switch, etc. Pressure switch error pressure switch closed with inducer off Issue with pressure switch, draft inducer not operating, debris in line, cracks in tubing, etc. Potential issue: Issue with wiring or line voltage polarity. Meaning: Open rollout switch Potential Issue: Blocked or cracked heat exchanger, blocked vent, low gas pressure, etc. Only a certified gas technician can check the gas pressures by using a manometer. Sometimes, even after troubleshooting the error codes, they can persist. If the red LED light on the furnace is blinking steadily, it means the unit is operating normally. If you see a green LED light, it means there is a demand for high heat. Note: if the breaker is tripped that means there is a possibility of a short circuit in the furnace or electric wire, you then should call an HVAC contractor immediately. Once you know the problem and the cost, you can decide if you want to proceed.