bc 2800 vet pdf

Bc 2800 vet pdf

Table Of Contents.

Large Color LCD display, 19 parameters Comprehensive patient data search Programmable multi-format printout; and 3 histograms in one screen function huge storage of 10, patient results with histograms. Multiple access for data input via keypad, keyboard or barcode scanner optional. Cerrar sugerencias Buscar Buscar. Saltar el carrusel. Carrusel anterior. Carrusel siguiente. Documentos de Profesional.

Bc 2800 vet pdf

All rights Reserved. This manual may refer to information protected by copyright or patents and does not convey any license under the patent rights or copyright of Mindray, or of others. Mindray intends to maintain the contents of this manual as confidential information. Disclosure of the information in this manual in any manner whatsoever without the written permission of Mindray is strictly forbidden. Release, amendment, reproduction, distribution, rental, adaptation, translation or any other. All other trademarks that appear in this manual are used only for. All information contained in this manual is believed to be correct. Mindray shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this manual. Mindray is responsible for the effects on safety, reliability and performance of this product, only if:. Exemptions Mindray's obligation or liability under this warranty does not include any transportation or other charges or liability for direct, indirect or consequential damages or delay resulting from the improper use or application of the product or the use of parts or accessories not approved by Mindray or repairs by people other than Mindray authorized personnel. A Index B Specifications C Precautions, Limitations and Hazards D Communication

Page Analog Inputs And Outputs 1. Page 85 Aperture v It measures the voltage v over the aperture.

The BC Vet is a compact, fully automatic hematology analyzer with 19 parameters for CBC testing and micro sampling technology. The user-friendly interface makes for easy and efficient workflow. Pre-programmed for 13 animals plus an addition 3 user-defined animals means it will satisfy the requirements of most vetinary clinics requirements. Cookies are important to the proper functioning of a site. To improve your experience, we use cookies to remember log-in details and provide secure log-in, collect statistics to optimize site functionality, and deliver content tailored to your interests. Click Agree and Proceed to accept cookies and go directly to the site or click on More Information to see detailed descriptions of the types of cookies and choose whether to accept certain cookies while on the site.

Table Of Contents. Table of Contents. Previous Page. Next Page. Page 3 Contents of this manual are subject to change without prior notice. All information contained in this manual is believed to be correct. Mindray shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this manual. Neglect of this may result in machine breakdown or personal injury. Be sure to operate the analyzer under the situation specified in this manual; otherwise, the analyzer will not work normally and the analysis results will be unreliable, which would damage the analyzer components and cause personal injury.

Bc 2800 vet pdf

All rights Reserved. For this Operators Manual, the issued date is This manual may refer to information protected by copyright or patents and does not convey any license under the patent rights or copyright of Mindray, or of others. Mindray intends to maintain the contents of this manual as confidential information. Disclosure of the information in this manual in any manner whatsoever without the written permission of Mindray is strictly forbidden. Release, amendment, reproduction, distribution, rental, adaptation, translation or any other derivative work of this manual in any manner whatsoever without the written permission of Mindray is strictly forbidden. All other trademarks that appear in this manual are used only for informational or editorial purposes. They are the property of their respective owners. Responsibility on the Manufacturer Party Contents of this manual are subject to change without prior notice.

San jose sharks uniforms

Page 5. If the difference between the reference WBC count time and the actual WBC count time is less than 2 seconds, the error has been removed; 7. A bar-code scanner can be connected to the RS port 1 of the analyzer. Page 90 Information column displays extra information regarding the event. Then the plunger moves upward and valves 6 and 5 are open so that the aspirated diluent is dispensed, through the NC end of valve 6, NC end of valve 5 and valves 4 and 3 to the lower part of the probe wipe. If you want to acquire help information, press [HELP]. This section gives detailed discussion about the setup of transmission parameter, RS serial port and the data transmission format, therefore, providing detailed information for the software engineers to program and for the user to conveniently perform transmission. If so, press [ENTER] and the analyzer will automatically flush the bath and dispense lyse and the test is done; 7. Be sure to avoid direct contact with the reagents that will hurt your eyes, skin and. Error Possible cause s Recommend action The analyzer 1. You can use it to scan the bar-coded sample IDs into the analyzer. If the problem still remains after a new filter has been installed, contact Mindray customer service department.

This manual may refer to information protected by copyrights or patents and does not convey any license under the patent rights of Mindray, nor the rights of others. Mindray does not assume any liability arising out of any infringements of patents or other rights of third parties. Mindray intends to maintain the contents of this manual as confidential information.

This analyzer can save maximum log files and once the maximum number has been reached, the newest log will automatically cover the oldest one. In this mode, the sample results are presented in a columnar fashion without histograms namely you can only see the parameter values. Take out the rinse pickup tube the one with a blue connector from the accessory box. Granulocytes Gran include neutrophils, eosinophils and basophils. Also, as required by regular maintenance, you should use the localizer to adjust the position of the sample probe monthly. See the figure below for the block diagram of the position-detecting circuit. Release, amendment, reproduction, distribution, rental, adaptation, translation or any other derivative work of this manual in any manner whatsoever without the written permission of Mindray is strictly forbidden. Other values will not be displayed. Note that you cannot change the sequence of the queued tasks. For this reason, the diluent is used to separate the cells so that they are drawn through the aperture one at a time as well as to create a conductive environment for blood analysis.

2 thoughts on “Bc 2800 vet pdf

Leave a Reply

Your email address will not be published. Required fields are marked *